The good oil
Stuttgart. Oil change intervals can be extended by around 25 percent by
means of a special sensor. Researchers from Daimler AG have developed a
practical system that allows them to monitor oil quality directly on board
a vehicle. This helps reduce operating costs, especially in commercial
vehicles.
The longer engine oil remains in use, the more it is susceptible to
impurities. Its quality is impaired and it gradually loses its lubricative
effect; this can even lead to engine damage. Timely oil changes are thus
indispensable. However, this is offset by material costs with up to 40
liters of oil in a truck's diesel engine, and loss of earnings due to
downtime during maintenance. An oil change should therefore take place as
early as necessary, but as late as possible.
Practical measurements
In view of the many external conditions to be taken into account, calculating
the precise maximum service interval on the basis of mathematical models
alone is difficult. The software must combine and assess various parameters:
the engine oil temperature, the frequency with which the engine is started,
mild or harsh conditions of use, and the particular circumstances of the
vehicle's operation and environment.
In order to determine the ideal moment for the next servicing, the Daimler
researchers therefore use a special sensor that provides clear readings.
This sensor, which is integrated into the oil circuit and registers the
characteristic parameters, allows the engine oil to be monitored directly.
Potential put to effect
To evaluate the quality of the oil, its so-called permittivity is calculated
by means of an AC potential applied between the interior and exterior pipes
of the oil-filled sensor. This parameter is a measure of the extent to which
the oil can transmit the applied electric field. If the engine oil is
contaminated by water or soot particles, it polarizes to greater extent and
its permittivity increases.
Slow flow
However, not all impurities can be registered with sufficient precision via
the electric field. The researchers use viscosity as a further quality marker
to detect any diesel fuel that may have found its way into the oil. In the
laboratory, they use an orifice viscometer - a container with a small
opening through which the oil flows out. The time required for this process
- the "efflux time" - which is dependent on the oil's flow characteristics,
is a direct measure of its viscosity. This in turn gives an indication of
the oil's remaining lubricative quality.
The Daimler researchers can also measure viscosity while the vehicle is in
motion by observing the oil's side-to-side motion in the sump. The more
slowly the oil moves, the higher its viscosity. This movement is registered
by the oil sensor and the viscosity calculated on this basis.
One single sensor, and the intelligently processed information which is
already available on board the vehicle, are sufficient to determine the
various parameters of the engine oil. This onboard oil quality surveillance
is currently being prepared for series application in commercial vehicles.
The resulting precise calculation of due times for maintenance stops will
allow oil change intervals to be extended by about one-fourth.
© 2008 Daimler AG. All rights reserved.
Mercedes-Benz engine oil recommendations
|